Skip to main content

Technoton DUT-E 2Bio

Status: In development: its code is written and tested on its own, but it does not work end to end on the platform yet. It cannot be installed.

KindVersionPublisherLicence
Device codec1.0.0ZAITRACKApache-2.0

What it does​

The LLS binary protocol (Omnicomm-compatible) of the DUT-E 2Bio and other fuel level sensors, relayed over TCP by a tracker or a serial-to-TCP gateway: the single-read answer (address, temperature, relative level, frequency, CRC-8 Maxim), and the poll that asks for it. Technoton's DUT-E operation manual (v9.1) says DUT-E 232/485 speak "DUT-E COM Protocol (extended LLS)"; the DUT-E COM document itself is not downloadable, so only the LLS single read is decoded. Not installable on its own: it decodes the sensor frames a tracker or gateway passes through, alongside that tracker's own codec.

  • Devices: fluid_level
  • Transport: tcp
  • Commands: locate-now, diagnostics-run
  • Capabilities: telemetry.fuel, telemetry.temperature, command.poll

How to use it​

Not yet: see its status above.

Configuration​

SettingTypeRequiredAllowed values and default
addressesarraynodefault [1]
channelsobjectnoSensor address → raw channel, up to59characters; temperature adds -fuel within CTM64character limit (default lls-
)

Credentials​

None.

Limits​

It runs in codec-runtime's WASM sandbox, within these limits (the platform's own ceilings bound them too):

  • Memory: 32 MB
  • Time per call: 100 ms
  • Instructions per call (fuel): 2,000,000,000
  • Largest message: 65,536 bytes
  • Calls per second: 8,000
  • Network: no network access
  • Its own key-value store: up to 1,024 keys of 4,096 bytes

Troubleshooting​

  • The device does not connect. Check the host and port its Connect page gives for your region, that the SIM has data and the APN is set, and that the device sends to that host (some send to the last server they were given).
  • It connects but no position arrives. The device must be registered with this protocol and the IMEI or serial it reports: a device the platform does not know, or a retired one, is refused when it connects. Trackers shows it as Check (never reported) until its first position.
  • Positions arrive with the wrong time. The protocol's timestamps are UTC; a device set to local time reports hours off. Set it to UTC.
  • A command does not reach the device. Only the commands listed under Commands are sent; the device must be online, and some models need the command enabled in their own configuration.

Source​

adapters/codecs/technoton-dut-e-2bio